Southwest
Environmental Limited| London |
| 02076 920 670 |
| Exeter |
| 01392 927 961 |
| Manchester |
| 01612 970 026 |
| Bristol |
| 01173 270 092 |
If you require Noise Data for a Report, or for any other reasons SWEL can provide noise monitoring services. We can provide a quotation based on the length of monitoring period required, we do not offer equipment only hire. The equipment is supplied with an operator, and installation service.
We will visit a site and set up the noise monitoring equipment. And provide baseline data. We can also supply a noise impact assessment, or a report summarizing results.
We can supply noise monitoring services across the UK. Please contact us for a quotation
It is quite common for a baseline report to be conducted prior to commencement of large construction works, this way the local enforcement bods, know how noisy you are being compared to "normal".
The below table shows the typical output from the monitoring equipment, we can derive any number of additional periodic data sets. Such as L Day and L Night in accordance with latest British Standards. If you would like to download a full set of example data then you do so: Example Environmental Baseline Noise Data
In summary however, the below table shows a typical output, that might be used in an Noise Assessment.
|
Item |
Value |
unit |
|
Date |
23/6/2006 |
|
|
Time |
13:00:00 |
|
|
Run Time |
00:14:59 |
hh:mm:ss |
|
Leq |
51.5 |
dBA |
|
Lepd |
36.4 |
dBA |
|
LAE |
80.8 |
dBA |
|
LAFmax |
76.0 |
dBA |
|
Peak |
100.5 |
dBC |
|
L1.0 |
62.5 |
dBA |
|
L5.0 |
56.4 |
dBA |
|
L10.0 |
53.2 |
dBA |
|
L50.0 |
41.8 |
dBA |
|
L90.0 |
40.4 |
dBA |
|
Lmin |
39.2 |
dBA |
|
Range |
30-100 |
dB |
|
Overload |
no |
|
|
Serial No. |
C17977FF |
|
|
Recal Due |
31/3/2007 |
|
|
Exp.Time |
0:14 |
hh:mm |
Accurate noise monitoring is fundamental to establishing the acoustic baseline of a site. Whether required for a planning application, industrial compliance, or to discharge a planning condition, professional noise data ensures that decisions are based on evidence rather than estimates. Our monitoring services provide the high-resolution data needed to support complex Noise Impact Assessments across the UK.
Monitoring is utilized across various sectors to ensure that noise levels remain within statutory limits or agreed thresholds. Key applications include:
All monitoring is conducted in accordance with relevant British Standards, such as BS 4142 for industrial noise or BS 5228 for construction sites. By integrating these findings into a broader Environmental Impact Assessment (EIA), we provide a holistic view of a project's footprint. Accurate data collection helps developers avoid costly litigation or enforcement actions resulting from noise complaints.
With over 15 years of industry experience and 900+ projects delivered, SWEL offers the technical authority required to manage acoustic risks. We utilize Class 1 sound level meters to provide the most accurate measurements possible. Our reports are designed to be robust under scrutiny from local authorities and environmental regulators. Whether you are looking for planning statement support or long-term site monitoring, we provide the expertise to secure your project's compliance.